For laboratory research use only. Not for human or animal use. A Certificate of Analysis is a lot-specific laboratory record. It is not a license for any use, a clinical claim, or dosing guidance.
How to read a peptide Certificate of Analysis
A Certificate of Analysis (COA) reports named analytical results for a specific lot or sample. This guide explains the fields laboratories typically see on a peptide COA — identity (LC-MS), purity (HPLC-UV), net peptide content, and related results — and how to match the document to the vial. It does not tell you how to use the material.
Every Simple Peptide lot is tested by an independent third-party lab. Current published COAs are from Freedom Diagnostics Testing (Franklin, TN). The lot COA is the controlling record for the material supplied.
What a COA is and is not
- It is a lot-specific report: product name, lot identifier, methods, and results for the sample that was tested.
- It is not a brochure, a lifetime guarantee for future lots, or permission for human or animal use.
- A marketing badge, a generic PDF, or a certificate that does not match the lot on the vial is not a lot-specific COA.
If the name, lot number, or search code does not match the container, stop and request the correct document. Do not treat an unmatched file as the record for that vial.
Match the vial before you read the numbers
Start at the top of the certificate, not at the purity line.
- Product name. Confirm it matches the label and the order. Watch for close variants (salt form, analog vs parent, blend vs single component).
- Lot or batch number. This must match the lot printed on the vial. It is the join key between the container, the archive, and the laboratory record.
- Accession or search code. On current Simple Peptide COAs this is typically a Search Code beginning with “Simp” plus an accession number. Keep it with the vial and notebook entry.
Look the lot up in the public COA archive. For the step-by-step archive and lab-lookup workflow, see How to verify a research peptide COA by lot number.
Identity: what LC-MS is confirming
Mass spectrometry (often shown as LC-MS) supports identity confirmation by relating observed mass information to the expected peptide. When the testing laboratory’s criteria are met, the COA typically states that identity was confirmed.
Identity confirmation answers “is this the expected molecule under the method used?” It does not, by itself, tell you how much of that molecule is present, and it is not a statement about any use of the material.
For a shorter method note, see HPLC-MS peptide analysis.
Purity: what HPLC-UV reports — and what a “purity %” does not tell you
High-performance liquid chromatography with UV detection (HPLC-UV) separates components in the tested sample and supports a purity assessment for the reported peak profile under the laboratory method in effect for that COA.
A purity percentage is a method result for that sample, not a slogan. It does not, by itself:
- identify the material (that is the identity test);
- state how much peptide is in the vial (see net peptide content);
- replace incoming checks in the receiving laboratory;
- authorize any human, veterinary, or consumer use.
Molecule-specific results vary. Always use the figures on the applicable lot PDF.
Net peptide content vs purity
These are two different measurements, and both can appear on one COA.
- HPLC purity describes the relative contribution of the main peak (or reported component) under the chromatographic method.
- Net peptide content describes how much of the measured material is the peptide itself, as opposed to other contributors the assay is designed to account for (for example residual moisture or counterions, when those are in scope for the method).
Read them together: a high purity result does not automatically tell you the net amount in the container, and a net-content result does not replace the identity or purity tests. How a laboratory uses those figures in its own work follows that laboratory’s SOP. This page does not provide amounts to use or prepare.
For Certificates of Analysis issued May 2026 and later, Simple Peptide lot records also document sterility, endotoxin, purity, and net peptide content when those results are included on that certificate. Earlier COAs reflect the testing standard in effect when they were issued. See lot release testing.
Other fields when they are present
- Appearance. Often described as a white or otherwise noted lyophilized powder. Compare this with what your laboratory records at receipt; it is a description, not a use instruction.
- Endotoxin. A laboratory test result on the sample, sometimes referencing a method such as a Limulus Amebocyte Lysate (LAL) assay. It is not a safety claim for human use.
- Microbial or sterility results. Lot-level laboratory results when they appear on that certificate. They describe the tested sample. They are not permission for clinical or compounding use.
If a field is absent, do not assume a newer testing panel applies retrospectively. Open the PDF for that lot.
Confirm the report with the issuing lab
Current published Simple Peptide COAs are issued by Freedom Diagnostics Testing (Franklin, TN), an independent laboratory. Each certificate carries a Search Code that can be entered on the laboratory’s public lookup at freedomdiagnosticstesting.com/?page_id=52 so you can compare the lab’s own copy with the file in the Simple Peptide COA archive.
A match means the same lot record is available from the issuer and from the archive. If a code does not return, contact Simple Peptide support with the product name, lot number, and Search Code. Do not invent a workaround.
No account is required to open the archive or the laboratory lookup. A verified research account is required only to order.
Field guide: what to look at, in order
This is a reading order for a typical peptide COA layout, not a copy of any one lot record and not a substitute for the PDF. Use the values printed on the certificate that belongs to your vial.
- Issuing laboratory name and document title.
- Product or material name.
- Lot or batch number (match the vial).
- Accession or Search Code (use it on the laboratory lookup).
- Identity method and statement (commonly LC-MS).
- Purity method and result (commonly HPLC-UV).
- Net peptide content, if reported.
- Any additional results (appearance, endotoxin, microbial or sterility).
- Report date and any method notes or conditions the laboratory lists.
Related documentation
- COA archive
- Verify a COA by lot number
- HPLC-MS peptide analysis
- Third-party testing
- Lyophilized peptide storage and handling
- Peptide purity data by product
- Peptide reference table
- Documentation hub
For laboratory research use only. Not for human or animal use. No dosing or clinical guidance is provided. The lot COA controls.